| Fire Extinguishers Dry powder type (stored pressure) fire extinguisher
'ABC' class of fire
Suitable For Fighting Fire Of Wood, cloth, Paper, Oil, Petrol, Kerosene, Flammable, Gases, Electrically Started Fires etc.
Technical Specification for ABC stored pressure type fire extinguishers |
| Capacity (in Kg) |
500 gms |
1 |
2 |
5 |
10 |
| IS Specification |
13849 |
13849 |
13849 |
13849 |
13849 |
| Jet Range ( In Mtrs.) |
1.5 |
2-4 |
2-4 |
4-5 |
<6 |
| Discharge Time (In Sec.) |
6-8 |
8-10 |
8-10 |
15-20 |
23-30 |
| Min. Discharge Quantity |
85% |
85% |
85% |
85% |
85% |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
30 |
30 |
30 |
30 |
30 |
| Discharge Outlet |
Direct Nozzle |
Direct Nozzle |
Direct Nozzle |
Direct Nozzle |
Direct Nozzle |
Carbon dioxide fire extinguisher
'BC' class of fire
Suitable For Fighting Fire Of All Flammable Liquids, Gases, Live & Delicate Machinery Fires, Electrical & Sophisticated Electronics Equipment fires.
Technical Specification for CO2 type fire extinguishers
|
| Capacity (In Kg.) |
2 |
3 |
4.5 |
6.5 |
9 |
22.5 |
| IS Specification |
2878 |
2878 |
2878 |
2878 |
2878 |
2878 |
| Jet Range (In Mtrs.) |
2 |
2 |
2.5-3 |
2.5-3 |
2.5-3 |
2.5-3 |
| Discharge Time (In Sec.) |
14-16 |
16-18 |
20-24 |
25-30 |
30-35 |
50-60 |
| Min. Discharge Quantity |
98% |
98% |
98% |
98% |
98% |
98% |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
250 |
250 |
250 |
250 |
250 |
250 |
| Working Pressure (Kg./Cm2) |
60-65 |
60-65 |
60-65 |
60-65 |
60-65 |
60-65 |
Dry chemical powder fire extinguisher
'BC' class of fire
Suitable For Fighting Fire Of Oils, Solvents, Gases, Paints, Varnish, Electrical Wiring, Live Machinery Fires, All Flamable Liquid & Gas Fires.
Technical Specification for Dry Chemical fire extinguishers
|
| Capacity (In Ltr.) |
5 |
10 |
25 |
50 |
75 |
| IS Specification |
2171 |
2171 |
10658 |
10658 |
10658 |
| Jet Range (In Mtrs.) |
4-5 |
<6 |
<6 |
8-10 |
10-12 |
| Discharge Time (In Sec.) |
15-20 |
25-30 |
25-30 |
40-50 |
50-60 |
| Min. Discharge Quantity |
90% |
90% |
85% |
85% |
85% |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
30 |
30 |
30 |
30 |
30 |
Mechanical foam fire extinguisher (AFFF)
'AB' class of fire
Suitable For Fighting Fire Of Petrol, Oil Paints, Sprits Chemicals, Flammable Liquids etc.
| Technical Specification |
MECH. FOAM |
MECH. FOAM |
MECH FOAM STORE PRESSURE |
| Capacity (in Ltr.) |
9 |
50 |
9 |
| IS Specification |
10204 |
13386 |
15397 |
| Jet Range (in Mtrs.) |
<6 |
10 |
<6 |
| Discharge Time (In Sec.) |
60-90 |
60-180 |
25-60 |
| Min.Discharge Quantity |
95% |
90% |
90% |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
30 |
30 |
30 |
Water CO2 fire extinguisher
'A' class of fire
Suitable For Fighting Fire Of Wood, Paper, Cotton, Jute etc.
| Technical Specification |
|
|
Water CO2 |
| Capacity (In Ltr.) |
9 |
9 |
50 |
| IS Specification |
6234 |
940 |
13385 |
| Jet Range (In Mtrs.) |
<6 |
<6 |
10 |
| Discharge Time (In Sec.) |
60-90 |
60-120 |
60-180 |
| Min. Discharge Quantity |
95% |
95% |
90% |
| Hydraulic Test Pressure of
Cylinder (Kg./Cm2) |
30 |
30 |
30 |
Top
|